| General specifications | 
	| Measuring functions | 
	  | 
	 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage | 
	| Intrinsic error | 
	  | 
	 Refers to the reference temperature range and is guaranteed for one year | 
	| Measuring rate | 
	  | 
	 2 measurements/second | 
	| Battery[1] | 
	  | 
	 One 9 volt alkaline (LR61) | 
	| Battery condition | 
	  | 
	 LO-BAT is displayed if voltage drops below 6.5 V | 
	| Voltages | 
	Between jacks H/C2 and E/C1: | 
	 250 Veff maximum (effective voltage) | 
	| Between jacks S/P2 and E/C1: | 
	 250 Veff maximum | 
	| Climatic class | 
	  | 
	 VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) | 
	| Temperature performance[2] | 
	Working: | 
	 -10 °C to +50 °C (+14 °F to +122 °F) | 
	| Operating: | 
	 0 °C to +35 °C (+32 °F to +95 °F) | 
	| Storage: | 
	 -20 °C to +60 °C (+68 °F to +140 °F) | 
	| Reference: | 
	 +23 °C ± 2 °C (+73 °F ± 4 °F) | 
	| Temperature coefficient | 
	  | 
	 ± 0.1 % of range per degree Kelvin | 
	| Safety | 
	  | 
	 IEC/EN 61010-1, 600 V CAT II, pollution degree 2 | 
	| Dimensions | 
	  | 
	 113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster | 
	| Weight | 
	  | 
	 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 | 
	| Note: | 
	  | 
	 [1]If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage. | 
	| Note: | 
	  | 
	 [2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use. | 
	| Electrical specifications | 
	| Maximum deviations: | 
	E1 Influence factor | 
	 Position | 
	| E1 Deviation influence | 
	 0 % | 
	| E2 Influence factor | 
	 Supply voltage | 
	| E2 Deviation influence | 
	 0 % | 
	| E3 Influence factor | 
	 Temperature E3 | 
	| E3 Deviation influence | 
	 2.3 % | 
	| E4 Influence factor | 
	 Serial interference voltage (20 V) | 
	| E4 Deviation influence | 
	 0.6 % | 
	| E5 Influence factor | 
	 Probe- and auxiliary probe resistance | 
	| E5 Deviation influence | 
	 10 % | 
	| Test voltage | 
	  | 
	 3.7 kV | 
	| Protection type | 
	  | 
	 IP 40; IEC/EN 60529 | 
	| Electromagnetic compatibility | 
	  | 
	 Emission: IEC/EN 61326 Class B | 
	|   | 
	 Immunity: IEC/EN 61326 Annex C | 
	| RE resistance measurement | 
	Measuring method | 
	 Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5 | 
	| Open circuit voltage | 
	 23 to 24 V ac | 
	| Short circuit current | 
	 > 50 mA ac | 
	| Measuring frequency | 
	 128 Hz | 
	| Maximum permissible overload | 
	 250 Veff | 
	| Measuring time | 
	  | 
	 8 seconds (average from when START is pressed) | 
	| Limit input | 
	  | 
	 Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient) | 
	| Automatic changeover of resolution | 
	RH | 
	 < 7 kΩ | 
	| Resolution | 
	 0.01 Ω | 
	| RH | 
	 < 50 kΩ | 
	| Resolution | 
	 0.1 Ω | 
	| RH | 
	 > 50 kΩ | 
	| Resolution | 
	 1 Ω | 
	| Interference voltage display dc + ac | 
	Vmax | 
	 30 Veff | 
	| Common mode rejection | 
	 > 80 dB at 50 Hz and 60 Hz | 
	| Ri | 
	 680 kΩ | 
	| Measuring uncertainty | 
	 < 10 % for pure ac and dc signals | 
	| Measuring range | 
	| 0.15 Ω to 20 Ω | 
	Resolution | 
	 0.01 Ω | 
	| Display range | 
	 0 to 19.99 Ω | 
	| 200 Ω | 
	Resolution | 
	 0.1 Ω | 
	| Display range | 
	 20 to 199.9 Ω | 
	| 2 kΩ | 
	Resolution | 
	 1 Ω | 
	| Display range | 
	 200 to 1999 Ω |